Introducing our range of laser power and single pulse energy sensor heads. If you want to measure the energy of each pulse within a train or burst up to 1 MHz repetition rate, see our Blink sensors.
(Almost) all of these laser sensors are available in 3 versions, depending on the connection mode:
- to an external laser power and energy meter (separate measuring console but with USB to PC connection)
- direct to computer or controller via USB (ta-dah, and we've already turned it into a meter!)
- direct to computer or controller via RS-232
Also ask about OEM sensors for integration into your machine or laser system.
The sensor + meter option is more expensive, but if you plan to expand to more sensors, it works out cheaper because the meter console will work with the new sensors without the need to pair them at the factory (PnP). Only one sensor can be connected at a time and not several.
Some features of these laser power and energy sensors are:
- Possibility to measure powers higher than nominal for a short period of time, maximum 2 minutes (depending on model).
- One laser power calibration at no cost (select wavelength or spectral range when ordering). Additional calibrations at extra cost. PTB - NIST traceable.
- Single pulse energy measurement option in addition to power (extra cost and must be specifically requested, depending on model).
All these products have 3 years warranty.
Power and energy sensor-meters, photodiodes, up to 50/500 mW:
Art. |
Power range |
Resolution |
Aperture |
Wl range |
MLP-PD-50-D9-UV |
10 µW - 50 mW |
100 nW |
9.5 mm |
200 - 1100 nm |
MLP-PD-50-D9-VIS |
10 µW - 50 mW |
100 nW |
9.5 mm |
400 - 1100 nm |
MLP-PD-50-D9-IR |
100 µW - 40 mW |
1 µW |
9.5 mm |
800 - 1800 nm |
MLP-PD-500-D9-VIS |
100 µW - 500 mW |
1 µW |
9.5 mm |
400 - 1100 nm |
Power and energy sensor-meters, thermopiles, low powers up to 40 W:
Art. |
Power range |
Energy range |
Aperture (mm) |
Wl range (µm) |
MLP-A-02-D12-BBF |
0.1 mW - 200 mW |
1 mJ - 200 mJ |
10 |
0.19 - 25 |
MLP-A-2-D12-BBF |
1 mW - 2 W |
1 mJ - 2 J |
10 |
0.19 - 25 |
MLP-A-2-D12-HPB |
1 mW - 2 W |
1 mJ - 2 J |
10 |
0.19 - 11 |
MLP-A-5-D12-BBF |
1 mW - 5 W |
10 mJ - 5 J |
10 |
0.19 - 25 |
MLP-A-10-D12-HPB |
10 mW - 10 W |
10 mJ - 15 J |
12 |
0.19 - 11 |
MLP-A-10-D20-BBF |
10 mW- 10 W |
10 mJ - 15 J |
20 |
0.19 - 25 |
MLP-A-10-D20-HPB |
10 mW- 10 W |
10 mJ - 15 J |
20 |
0.19 - 11 |
MLP-A-30-D25-HPB |
20 mW - 30 W |
50 mJ - 45 J |
25 |
0.19 - 11 |
MLP-A-40-D25-HPB |
20 mW - 40 W |
50 mJ - 60 J |
25 |
0.19 - 11 |
MLP-A-40-D40-HPB |
20 mW - 40 W |
50 mJ - 60 J |
40 |
0.19 - 11 |
MLP-A-40/200-D25-HPB |
150 mW - 40 W |
200 mJ - 200 J |
25 |
0.19 - 11 |
MLP-A-40/200-D40-HPB |
100 mW - 40 W |
150 mJ - 200 J |
40 |
0.19 - 11 |
MLP-A-40/200-D60-HPB |
200 mW - 40 W |
250 mJ - 200 J |
60 |
0.19 - 11 |
Power and energy sensor-meters, thermopiles, medium power up to 600 W:
Art. |
Power range |
Energy range |
Aperture (mm) |
Wl range (µm) |
MLP-A-200-D25-HPB |
0.2 - 200 W |
0.5 - 250 J |
25 |
0.19 - 11 |
MLP-A-200-D25-SHC |
0.2 - 200 W |
0.5 - 250 J |
25 |
0.19 - 11 |
MLP-A-200-D40-HPB |
0.2 - 200 W |
0.5 - 250 J |
40 |
0.19 - 11 |
MLP-A-200-D40-SHC |
0.2 - 200 W |
0.5 - 250 J |
40 |
0.19 - 11 |
MLP-A-200-D60-HPB |
0.3 - 200 W |
1 - 250 J |
60 |
0.19 - 11 |
MLP-A-200-D60-SHC |
0.3 - 200 W |
1 - 250 J |
60 |
0.19 - 11 |
MLP-A-300-D60-HPB |
0.5 - 300 W |
1 - 400 J |
60 |
0.19 - 11 |
MLP-A-600-D40-HPB |
0.5 - 600 W |
1 - 800 J |
40 |
0.19 - 11 |
MLP-A-600-D60-SHC |
0.5 - 600 W |
1 - 800 J |
60 |
0.19 - 11 |
MLP-W-200-D40-HPB |
0.2 - 200 W |
1 - 300 J |
40 |
0.19 - 11 |
MLP-W-200-D40-SHC |
0.2 - 200 W |
1 - 300 J |
40 |
0.19 - 11 |
MLP-W-600-D30-HPB |
0.5 - 600 W |
2 - 800 J |
30 |
0.19 - 11 |
MLP-W-600-D30-SHC |
0.5 - 600 W |
2 - 800 J |
30 |
0.19 - 11 |
MLP-W-600-D70-HPB |
0.5 - 600 W |
2 - 800 J |
70 |
0.19 - 11 |
MLP-W-600-D70-SHC |
0.5 - 600 W |
2 - 800 J |
70 |
0.19 - 11 |
Power and energy sensor-meters, thermopiles and calorimeters, high power up to 40 KW;
Art. |
Power range |
Energy range |
Aperture (mm) |
Wl range (µm) |
MLP-A-1200-D60-SHC |
2 W - 1200 W |
5 - 1200 J |
60 |
0.19 - 11 |
MLP-W-1500-D40-HPB |
4 W - 1500 W |
5 - 2250 J |
40 |
0.19 - 11 |
MLP-W-1500-D40-SHC |
4 W - 1500 W |
5 - 2250 J |
40 |
0.19 - 11 |
MLP-W-3000-D55-HPB |
6 W - 3 kW |
na |
55 |
0.19 - 11 |
MLP-W-3000-D55-SHC |
6 W - 3 kW |
na |
55 |
0.19 - 11 |
MLP-W-6000-D55-SHC |
15 W - 6 kW |
na |
55 |
0.19 - 11 |
MLP-W-12K-D55-SHC |
100 W - 12000 W |
na |
55 |
0.19 - 11 |
Art. |
Power range |
Aperture (mm) |
Wl range (µm) |
MPL-Extreme-20 |
0.5 – 20 KW |
35 |
1.05 - 1.09 |
MPL-Extreme-40 |
0.5 – 40 KW |
35 |
1.05 - 1.09 |
Power and energy sensor-meters, thermopiles for pulsed lasers, up to 20J:
Art. |
Power range |
Energy range |
Aperture (mm) |
Wl range (µm) |
MLP-10-BB-D12-L |
2 mW - 10 W |
50 mJ - 10 J |
12 |
0.4 - 2 |
MLP-10-BB-D25 |
2 mW - 10 W |
50 mJ - 10 J |
25 |
0.4 - 5.2 |
MLP-10VA-D25 |
2 mW - 10 W |
50 mJ - 10 J |
25 |
0.25 - 0.4 |
MLP-10VC-D25 |
2 mW - 10 W |
50 mJ - 10 J |
25 |
0.19 - 0.25 |
MLP-20-BB-D40 |
40 mW - 20 W |
100 mJ - 20 J |
40 |
0.4 - 5.2 |
MLP-20VA-D40 |
40 mW - 20 W |
100 mJ - 20 J |
40 |
0.25 - 0.4 |
MLP-20VC-D40 |
40 mW - 20 W |
100 mJ - 20 J |
40 |
0.19 - 0.25 |
Power and energy sensor-meters, thermopiles for high fluence lasers, up to 60J:
Art. |
Power range |
Energy range |
Aperture (mm) |
Wl range (µm) |
MLP-A-10-D12-DIF |
10 mW - 10 W |
10 mJ - 15 J |
12 |
0.2 - 2.1 |
MLP-A-30-D12-SHC-L |
20 mW - 30 W |
100 mJ - 45 J |
12 |
0.2 - 1.1 |
MLP-A-30-D18-DIF |
25 mW - 30 W |
100 mJ - 45 J |
18 |
0.2 - 2.1 |
MLP-A-40-D33-DIF |
25 mW - 40 W |
100 mJ - 60 J |
33 |
0.2 - 2.1 |
Fast fower and energy sensor-meters, thermopiles: MLP-Blink-FR:
Fast response, typ. 90 ms
Art. |
Power range |
Energy range |
Aperture (mm) |
Wl range (µm) |
MLP-BL-A-5W-16-K |
25 mW - 5 W |
20 mJ - 5 J |
16 x 16 |
0.2 - 25 |
MLP-BL-A-8W-16-K |
25 mW - 8 W |
20 mJ - 5 J |
16 x 16 |
0.2 - 25 |
MLP-BL-A-25W-16-K |
25 mW - 25 W |
20 mJ - 5 J |
16 x 16 |
0.2 - 25 |
MLP-BL-W-50W-16-K |
30 mW - 50 W |
20 mJ - 5 J |
16 x 16 |
0.2 - 25 |
MLP-BL-A-5W-12-A |
50 mW - 5 W |
50 mJ - 10 J |
12 x 12 |
0.5 - 11 |
MLP-BL-A-10W-12-A |
50 mW - 10 W |
50 mJ - 10 J |
12 x 12 |
0.5 - 11 |
MLP-BL-A-50W-12-A |
100 mW - 50 W |
50 mJ - 10 J |
12 x 12 |
0.5 - 11 |
MLP-BL-W-100W-12-A |
100 mW - 100 W |
50 mJ - 10 J |
12 x 12 |
0.5 - 11 |
Our categories in laser power and energy measurement:
- sensor heads
- ultra-fast Blink sensors
- meters
- hand-held probes
All these products have a 3-year warranty.
At PCL we are the LaserPoint distributors in Portugal and Spain.
If you work with lasers do not forget to consult our sections:
- laser protection products: goggles, windows, barriers, curtains, cabins, clothing
- consultancy and additionally training in laser safety
- laser power and energy measurement
- laser beam profile analysis
More information: ventas@procarelight.com / +34 605 024 420